heat-imaging | |
Sensor type | Vanadium oxide (VOx) micro radiation calorimeter |
Maximum image size | 640 × 512 |
Pixel size | 12μm |
Response band | 8~14 μm |
NETD (noise equivalent temperature difference) | ≤40mK(@25 °C,F#1.0) |
angle of field | 48.3°(H) x 38.6°(V),62.4°(D) |
Thermal imaging lens focal length | 9.1mm |
image display | |
display resolution | 640 × 512 |
frame rate | 30Hz |
acoustic image | support |
brightness control | support |
Fake color mode | Support 15 modes such as white heat, black heat, fusion 1, rainbow, fusion 2, iron red 1 and iron red 2 |
contrast control | support |
system function | |
joggle | USB2.0 interface |
system parameter | |
Storage temperature | -45 °C ~ + 75 °C |
Storage humidity | <90% RH |
working temperature | -40 °C~60 °C |
Working humidity | <90% RH |
weight | ≤23g |
size | 20mm x 20mm x 20mm (excluding lens) |
power | ≤0.7W |
power input | DC 5V±5% |
Temperature measurement function | |
Temperature measurement rules | Normal mode: full screen temperature measurement Expert mode: 10 points, 10 boxes, 1 line, a total of 21 temperature measurement rules |
presentation of information | Support full screen temperature data output |
Temperature range | -20 °C~+150°C and 100 °C~550 °C |
Temperature measurement distance | 2-18m is optional |
temperature measurement accuracy | ± 2 °C or ±2% of the reading (take the maximum value) |